Application Example of Factory Workshop
Plant area of ??3,500 square meters, 3.5 meters high floor, the number of workers 800, the summer workshop temperature of about 40 ¡æ. Dense work and the fact that the equipment has a strong smell of the workshop so that the air hygiene conditions are very poor, often workers because of too hot or anoxia and fainted, an increase of a large number of accident costs, the original plant equipped with a large number of fans and fans, But can not improve the air quality and oxygen content. The plant has also envisaged the installation of traditional air-conditioning system, but the estimated, according to 15 square meters a cooling capacity design, a working day (12 hours) required electricity 2240 yuan, the initial installation fee of 700,000 yuan, into large and can not solve Indoor air health problems, so that the plant canceled the installation of traditional compressor air conditioning system program.
ZLG science and technology energy-saving environmental protection air conditioning to provide practical solutions
According to the actual situation of the garment factory, we installed 40 HB180 energy-saving environmental protection air-conditioning in the factory, each air volume of 18000 cubic meters / hour, the total air volume of 720000 cubic meters / hour, the air outlet hanging height of 2.5 meters Gas times about 60 times / hour, the air supply speed of about 5m / s. ZLG energy saving and environmental protection air conditioning put into use, made a good ventilation, ventilation effect, while adjusting the effect of indoor temperature. After installing ZLG environmental protection air conditioning, the air quality of the workshop is improved remarkably. When the outdoor temperature is hot, the temperature of the workshop can be reduced by more than 10 ¡ã C, and the number of ventilation times of 60 times per hour has also been solved. The
In the initial investment and operating costs, the installation of traditional compressed air-conditioning system, the cost of 700,000 yuan, and the installation of 40 ZLG science and technology environmental protection and environmental protection air conditioning costs only 18 million, saving 520,000 yuan, in terms of operation, Traditional compressed air-conditioning system is 2240 yuan a day (according to 12 hours, 1 yuan / kWh), and ZLG science and technology environmental protection air-conditioning day power consumption is 528 yuan, comprehensive comparison, energy saving and environmental protection is the best choice.
06:07 Publié dans cooling equipment | Lien permanent | Commentaires (0)
05/04/2017
What cooling equipment used in the workshop
11:45 Publié dans cooling equipment | Lien permanent | Commentaires (0)
22/03/2017
The installation location of the fan is specified
Greenhouse ventilation and cooling system equipment installation requirements of the fan
1, the fan should be installed in the greenhouse under the wind on the side wall or gable, if the fan must be installed on the wind side, the design of the total flow of ventilation at least 10 to write.
2, the fan exhaust and adjacent obstacles (such as building walls) should be greater than the distance between the fan wheel diameter of 1.5 times.
3, the design of the number of fans for more than one, it is recommended that all the fans at regular intervals divided into two groups or three groups, in order to control the ventilation and cooling equipment at the same time the number of fans running, according to actual needs, adjust the ventilation flow and keep the greenhouse Air flow is generally uniform.
4, the fan should be outside the blinds, to prevent downtime when the air back or pests and dirt intrusion. Fan inside the application of protective cover, to prevent the body and debris contact with moving parts. If the distance between the protective cover net and the moving parts is within 100 mm, the diameter of the wire used in the ventilation and cooling equipment shall not be less than 1.50, mm and the hole shall not be greater than 13 mm; if the protective net is to the moving parts Distance of more than 100, mm, can use the diameter of 2.7, mm steel wire mesh, aperture size up to 50, mm.
5, the design of the number of fans G3, it is recommended that one or more than two-speed motor drive, in order to more flexible and flexible ventilation control.
09:54 Publié dans Nature et environnement | Lien permanent | Commentaires (0)